Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Ä¡°ú¿ë CAD ÇÁ·Î±×·¥ÀÇ ·»´õ¸µ È­¸é»ó °Å¸®ÃøÁ¤ ºñ±³ºÐ¼®

Comparative analysis of distance measurement on the rendering screen between dental CAD programs

´ëÇÑÄ¡°úº¸Ã¶ÇÐȸÁö 2021³â 59±Ç 1È£ p.11 ~ 17
Â÷öȣ, ÀÓ¼±¿µ, ¹æÁÖÇõ, ±è¼º¾Æ, ±è¼º¿ë, ÀÌ¿ë»ó,
¼Ò¼Ó »ó¼¼Á¤º¸
Â÷öȣ ( Cha Cheol-Ho ) - Veterans Health Service Medical Center Department of Prosthodontics
ÀÓ¼±¿µ ( Lim Seon-Young ) - Veterans Health Service Medical Center Department of Prosthodontics
¹æÁÖÇõ ( Bang Ju-Hyuk ) - Veterans Health Service Medical Center Department of Prosthodontics
±è¼º¾Æ ( Kim Seong-Ah ) - Veterans Health Service Medical Center Department of Prosthodontics
±è¼º¿ë ( Kim Seong-Yong ) - Veterans Health Service Medical Center Department of Prosthodontics
ÀÌ¿ë»ó ( Lee Yong-Sang ) - Veterans Health Service Medical Center Department of Prosthodontics

Abstract

¸ñÀû: º» ¿¬±¸ÀÇ ¸ñÀûÀº 3°¡Áö Á¾·ùÀÇ CAD ÇÁ·Î±×·¥µé¿¡ µû¶ó ·»´õ¸µ È­¸é Â÷ÀÌ°¡ CAD ÇÁ·Î±×·¥ »óÀÇ °Å¸® ÃøÁ¤¿¡¼­ÀÇ Â÷ÀÌ·Î ³ªÅ¸³ª´ÂÁö ¾Ë¾Æº¸°íÀÚ ÇÔÀÌ´Ù.

Àç·á ¹× ¹æ¹ý: Ä¡°ú¿ë ½ºÄ³³Ê Æò°¡¸¦ À§ÇØ Á¦½ÃµÈ ISO 12836 ±Ô°Ý Àη¹ÀÌ ¸ðÇüÀ» 70% Ãà¼ÒÇÑ ¸ðµ¨À» Á¦ÀÛÇÏ¿´´Ù. ÀÌ ¸ðµ¨À» Trios II (3Shape, Denmark)¸¦ »ç¿ëÇÏ¿© ÃÑ 15ȸ ¹Ýº¹ÇÏ¿© ¿¬¼ÓÀûÀ¸·Î ½ºÄµÀ» ½ÃÇàÇÏ¿´´Ù. Ãâ·ÂµÈ STL ÆÄÀÏÀ» ÀÌ¿ëÇÏ¿© 3Shape CAD, inLab 15, ExoCAD ÇÁ·Î±×·¥À» ÅëÇØ ÀÎÁ¢ÇÑ Á¡°¢ °£ ¼öÆò °Å¸®(H)¿Í ¼öÁ÷ °Å¸®(V)¸¦ °¢°¢ ÃøÁ¤ÇÏ´Â ½ÇÇèÀ» ¼öÇàÇÏ¿´°í, °¢ ½ÇÇ踶´Ù CAD ÇÁ·Î±×·¥ Á¾·ù¿¡ µû¶ó 3°³ÀÇ ±ºÀ¸·Î ¼³Á¤ÇÏ¿´´Ù. One-way ANOVA test¸¦ ÅëÇØ Åë°è ºÐ¼®ÇÏ¿´°í, Dunnett T3¹ýÀ¸·Î »çÈĺм®À» ½ÃÇàÇÏ¿´´Ù.

°á°ú: ¼öÆò°Å¸®¿Í ¼öÁ÷°Å¸® ÃøÁ¤¿¡¼­ ¸ðµÎ CAD ÇÁ·Î±×·¥¿¡ µû¸¥ ¼¼ ±º °£ÀÇ ÃøÁ¤°ª Æò±ÕÀÇ À¯ÀÇÇÑ Â÷ÀÌ´Â ¾ø¾ú´Ù (P > .05).

°á·Ð: Ä¡°ú¿ë CAD ÇÁ·Î±×·¥»ó¿¡¼­ Àη¹ÀÌ ¸ðÇüÀÇ ¼öÆò, ¼öÁ÷ Á÷¼±°Å¸®¸¦ ÃøÁ¤ÇÒ ¶§, ÇÁ·Î±×·¥ °£ÀÇ ·»´õ¸µ È­¸é Â÷ÀÌ¿¡ µû¸¥ ¿µÇâÀº ¾ø´Ù.

Purpose: This study was to find out whether the rendering screen difference affect to measuring distance in a CAD program according to three types of CAD programs.

Materials and methods: The model presented in ISO 12836 for dental scanner evaluation was reduced by 70%. This model was repeatedly scanned 15 times using Trios II (3Shape, Denmark). Using the output STL file, 3Shape CAD, inLab 15, and ExoCAD programs were used to measure the horizontal distance (H) and vertical distance (V) between adjacent point angle, and for each experiment, three groups were set according to the CAD program type. Statistical analysis was performed using One-way ANOVA test and post hoc was performed using Dunnett T3 test.

Results: In the horizontal and vertical distance measurement, there was no difference in the average of the measured values between the three groups according to the CAD program (P>.05).

Conclusion: There were no effect of the difference in the rendering screen in the horizontal and vertical linear distance measurements of the inlay model on the dental CAD program.

Å°¿öµå

Computer aided design; Computer aided manufacturing; º¯¿¬ ÀûÇÕ
Computer-aided design; Computer-aided manufacturing; Marginal adaptation