Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

´ÜÀÏ Ä¡°ü ¼öº¹ ½Ã ±¸°­½ºÄ³³Ê¸¦ ÀÌ¿ëÇÑ ±³ÇÕÆò°¡ È°¿ë Áõ·Êº¸°í

A case report of single crown restoration using an intraoral scanner for occlusal evaluation

´ëÇÑÄ¡°úº¸Ã¶ÇÐȸÁö 2021³â 59±Ç 3È£ p.341 ~ 349
¼ÛÁعü, ÀÌÁ¾Çõ, ÇϽ·æ, ÃÖÀ¯¼º, ÃÖ¼±¿µ,
¼Ò¼Ó »ó¼¼Á¤º¸
¼ÛÁعü ( Song Jun-Beom ) - Dankook University School of Dentistry Department of Prosthodontics
ÀÌÁ¾Çõ ( Lee Jong-Hyuk ) - Dankook University School of Dentistry Department of Prosthodontics
ÇϽ·æ ( Ha Seung-Ryong ) - Dankook University School of Dentistry Department of Prosthodontics
ÃÖÀ¯¼º ( Choi Yu-Sung ) - Dankook University School of Dentistry Department of Prosthodontics
ÃÖ¼±¿µ ( Choi Sun-Young ) - Dankook University School of Dentistry Department of Prosthodontics

Abstract

µðÁöÅÐ ¹æ½ÄÀ» ÀÌ¿ëÇÑ ±³ÇÕÆò°¡´Â Á¾·¡ÀÇ ¹æ½ÄÀÎ ±³ÇÕÁö¿Í occlusion foil µî¿¡ ºñÇØ ±â·Ï, ºñ±³, ºÐ¼® µîÀÌ ½±°í °£ÆíÇÏ¸ç °´°üÀû À̶ó´Â ÀåÁ¡ÀÌ ÀÖ´Ù. ÀÌ¿¡ º» Áõ·Êº¸°í¿¡¼­´Â ±³ÇÕÆò°¡¿¡ µðÁöÅÐ ±â¼úÀ» È°¿ëÇÏ°íÀÚ ´ÜÀÏ ÀüÀå°ü ¼öº¹ÀÌ ÇÊ¿äÇÑ È¯ÀÚ¿¡¼­ ±¸°­½ºÄ³³Ê(i500, Medit, Seoul, Korea)¸¦ ÀÌ¿ëÇÏ¿© ¸Å ³»¿ø½Ã ±³ÇÕÀ» Æò°¡ÇÏ¿´À¸¸ç, ºñ±³¸¦ À§ÇÏ¿© ±³ÇÕÁö¸¦ ÀÌ¿ëÇÑ ±³ÇÕ°ü°è È®Àΰú µðÁöÅÐ ±³Çպм®Àåºñ(Dental prescale II, GC corporation, Tokyo, Japan)¸¦ ÀÌ¿ëÇÏ¿© ±³ÇÕ°ü°è¸¦ Æò°¡ÇÏ¿´´Ù. Ä¡·á°úÁ¤¿¡¼­ ±¸°­½ºÄ³³Ê¸¦ ÀÌ¿ëÇÑ ¹æ¹ý°ú ±âÁ¸ÀÇ ±³ÇÕÁö¸¦ ÀÌ¿ëÇÑ ¹æ¹ýÀÌ À¯»çÇÑ °á°ú¸¦ º¸¿© ÇâÈÄ ÀÓ»óÀûÀ¸·Î À¯¿ëÇÏ°Ô »ç¿ëµÉ ¼ö ÀÖÀ» °ÍÀ¸·Î »ç·áµÇ¾ú´Ù.

The evaluation of occlusion using digital methods is easier and simpler in terms of recording, comparison, analysis, and objectivity compared to existing methods such as articulating paper and occlusion foil. The purpose of this case report was utilizing the digital method for evaluating occlusion. The occlusion of patient requiring full veneer crown restoration was evaluated using an intraoral scanner (i500, Medit, Seoul, Korea) at every visit. The occlusion was also assessed using conventional articulating paper and a digital occlusal analysis system (Dental prescale II, GC corp., Tokyo, Japan) for comparison. Throughout the treatment process, the intraoral scanner and the conventional articulating paper method showed similar outcomes. The results suggest that the use of digital evaluation system is highly probable in the near future.

Å°¿öµå

CAD-CAM; µðÁöÅÐ Àλóäµæ; µðÁöÅÐ ±¸³» ½ºÄµ; °íÁ¤¼º º¸Ã¶¹°; ±¸°­½ºÄ³³Ê; ±³ÇÕÆò°¡
Computer-aided design and computer-aided manufacturing (CAD-CAM); Digital impression; Digital intraoral scan; Fixed prosthesis; Intraoral scanner; Occlusal evaluation

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

  

µîÀçÀú³Î Á¤º¸

KCI
KoreaMed