Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

º¸Ã¶¹° ¼öº¹ ÇüÅ¿¡ µû¸¥ T-Scan Novus¿Í Dental prescale II¸¦ ÀÌ¿ëÇÑ ±³ÇÕ·Â Æò°¡ È°¿ë Áõ·Ê

Evaluation of occlusal strength using T-Scan Novus and Dental prescale II in dental prosthodontic treatments: A case report

´ëÇÑÄ¡°úº¸Ã¶ÇÐȸÁö 2023³â 61±Ç 2È£ p.160 ~ 178
ÃÖ¼öÇö, ÃÖÀ¯¼º, ÀÌÁ¾Çõ, ÇϽ·æ,
¼Ò¼Ó »ó¼¼Á¤º¸
ÃÖ¼öÇö ( Choi Su-Hyun ) - 
ÃÖÀ¯¼º ( Choi Yu-Sung ) - 
ÀÌÁ¾Çõ ( Lee Jong-Hyuk ) - 
ÇϽ·æ ( Ha Seung-Ryong ) - 

Abstract

º¸Ã¶ Ä¡·á ½Ã ±³ÇÕ°ü°èÀÇ Áø´Ü°ú ºÐ¼®Àº Áß¿äÇÑ ¿ä¼Ò Áß ÇϳªÀÌ´Ù. Ä¡·á ½ÃÇà Àü ¸é¹ÐÇÑ ±³Çպм® ¹× Æò°¡°¡ ¼±ÇàµÇ¾î ¾ÈÁ¤ÀûÀÎ ¾Ç°£ °ü°è¸¦ ȸº¹½ÃÄÑ ÁÖ¾î¾ß Çϸç, Ä¡·á °úÁ¤ ¹× Á¤±â °ËÁø ½Ã¿¡µµ ÀÌ¿¡ ´ëÇÑ Æò°¡´Â ÇʼöÀûÀÌ´Ù. ÃÖ±Ù, Ä¡°ú¿ë ±â±â¿Í µðÁöÅРó¸® ¹æ½ÄÀÇ ¹ß´Þ·Î ȯÀÚÀÇ ±³ÇÕ°ü°è¸¦ ±â·ÏÇÒ ¼ö ÀÖ´Â »õ·Î¿î Á¤·®Àû ºÐ¼® ¹æ¹ýµéÀÌ ¼Ò°³µÇ°í ÀÖ´Ù. ±× Áß T-Scan Novus (Tekscan Inc., S. Boston, MA, USA)´Â ¾Ð·ÂÃøÁ¤¼¾¼­¸¦ ÀÌ¿ëÇÏ¿© »óÇÏ¾Ç Ä¡¾ÆÀÇ ÃʱâÁ¢ÃËÁ¡°ú ±³ÇÕÁ¢ÃËÁ¡ÀÇ »ó´ëÀûÀÎ °­µµ¸¦ ³ªÅ¸³»¸ç Ä¡¾ÆÀÇ ±³ÇÕÁ¢ÃË ½Ã°£, ±³ÇÕ·ÂÀÇ ÀüÈĹæ, Á¿ì±ÕÇüÀ» ºñ±³ÇÒ ¼ö ÀÖ´Ù. Dental prescale II (GC Co., Tokyo, Japan)´Â ¾Ð·Â°¨ÁöÇʸ§À» ÀÌ¿ëÇÏ¿© ±³ÇÕÁ¢ÃËÁ¡À» ½ºÄµÇÏ¿© Á¢ÃËÁ¡ÀÇ ¹Ðµµ¸¦ ºÐ¼®ÇÏ´Â ¹æ¹ýÀ¸·Î ÃÖ´ëÇÑ ÀÚ¿¬½º·¯¿î ±³ÇÕ»óÅ ġ¿­ÀÇ ±³ÇÕ·Â ºÐÆ÷¿Í °­µµ¸¦ ÃøÁ¤ÇÒ ¼ö ÀÖ´Ù. ȯÀÚÀÇ Ä¡¾Æ »ó½Ç ºÎÀ§¿Í ¹üÀ§¿¡ µû¶ó 4-unit °íÁ¤¼º ±¹¼ÒÀÇÄ¡, °¡Ã¶¼º ±¹¼ÒÀÇÄ¡, ÃÑÀÇÄ¡, ¿ÏÀü±¸°­È¸º¹¼úÀ» ½ÃÇàÇÏ¿´´Ù. ÀûÀýÇÑ ±³ÇÕ ºÐ¼®À» À§ÇØ, ÃÊÁø, °¢ Ä¡·á ´Ü°è, Ä¡·á Á÷ÈÄ ¹× Á¤±â°ËÁø ½ÃÀÇ È¯ÀÚÀÇ ±³ÇÕÀ» T-Scan Novus¿Í Dental prescale II¸¦ ÀÌ¿ëÇÏ¿© Á¤·®ÀûÀ¸·Î ºñ±³, Æò°¡ÇÏ¿´´Ù. º¸Ã¶¼öº¹ Ä¡·á°úÁ¤¿¡¼­ ±³ÇÕ ºÐ¼®¿¡ ´ëÇÑ ÀÌÇصµ¸¦ Á¦°íÇÒ ¼ö ÀÖ¾ú°í, ±â´É ¹× ½É¹ÌÀûÀ¸·Î ȯÀÚ¿Í ¼úÀÚ ¸ðµÎ ¸¸Á·ÇÒ ¸¸ÇÑ °á°ú¸¦ ¾ò¾ú±â¿¡ À̸¦ º¸°íÇÏ°íÀÚ ÇÑ´Ù.

Diagnosis and analysis of occlusal relationships are important factors in prosthetic treatment. A thorough occlusion analysis and evaluation should be performed before treatment to restore a stable interocclusal relationship. Analysis and evaluation are essential during the treatment process and at regular follow-ups. Recently, with the development of dental equipment and digital processing methods, new quantitative analysis methods that can record the patient¡¯s occlusal relationship have been introduced. Among them, the T-Scan Novus (Tekscan Inc., S. Boston, MA, USA) displays the strength of the initial contact point and the occlusal contact point of the teeth using a pressure sensor. With this, occlusal contact time of the teeth, anteroposterior and left-right balance of occlusal force can be compared. The Dental prescale II (GC Co., Tokyo, Japan) scans the occlusal contact point using a pressure-sensing film and analyzes the density of the contact point. It can measure the distribution and strength of the occlusal force of the teeth in the most natural occlusion state. Based on this, appropriate prosthetic treatment (four-unit fixed partial denture, removable partial denture, complete denture, and complete oral restoration cases) was performed according to the area and extent of the patient¡¯s tooth loss. The patient¡¯s occlusion at the first visit, treatment stage, right after treatment, and regular follow-up were compared and evaluated using a quantitative method for appropriate occlusion analysis using T-Scan Novus and Dental prescale II. This report enhances the understanding of occlusion analysis during prosthetic restoration. The results satisfied both the clinician and patients in terms of function and aesthetics.

Å°¿öµå

T-Scan Novus; Dental prescale II; µðÁöÅÐ ±³Çպм®; Á¤·®Àû ºÐ¼®; ±³ÇÕ·Â Æò°¡
T-Scan Novus; Dental prescale II; Digital occlusal analysis; Quantitative analysis; Occlusal strength evaluation

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI
KoreaMed