Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Àӽà ÀÇÄ¡¿Í ÀÌÁß µðÁöÅÐ ½ºÄ³´× ±â¹ýÀ» È°¿ëÇÑ Àü¾Ç °íÁ¤¼º ÀÓÇöõÆ® ¼öº¹ Áõ·Ê

Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report

´ëÇÑÄ¡°úº¸Ã¶ÇÐȸÁö 2023³â 61±Ç 3È£ p.245 ~ 256
½Å¼®Çö, ¹ÚÂùÀÍ, °­¼¼ÇÏ, ¹®ÁöÀº, ¿À¹Î¼®, ¹Úö¹Î, Àü¿ìÁø, ÇѼº±¸, ±è¼±Àç, ÃÖ¼öÁø,
¼Ò¼Ó »ó¼¼Á¤º¸
½Å¼®Çö ( Shin Seok-Hyun ) - 
¹ÚÂùÀÍ ( Park Chan-Ik ) - 
°­¼¼ÇÏ ( Kang Se-Ha ) - 
¹®ÁöÀº ( Moon Ji-Eun ) - 
¿À¹Î¼® ( Oh Min-Seok ) - 
¹Úö¹Î ( Park Chul-Min ) - 
Àü¿ìÁø ( Jeon Woo-Jin ) - 
ÇѼº±¸ ( Han Seong-Gu ) - 
±è¼±Àç ( Kim Sun-Jae ) - 
ÃÖ¼öÁø ( Choi Su-Jin ) - 

Abstract

ÀÓÇöõÆ® °íÁ¤¼º º¸Ã¶¹° Á¦ÀÛ ½Ã µðÁöÅÐ ½Ã½ºÅÛÀ» ÀÌ¿ëÇÏ¿© ¼öº¹ÇÒ ¶§, 3Â÷¿øÀûÀÎ ÀÓÇöõÆ® À§Ä¡ÀÇ ±¸³» ½ºÄµ°ú Àӽà ÀÇÄ¡ ȤÀº Àӽà º¸Ã¶¹° ÀåÂø ÈÄ ±¸³» ½ºÄµÀ» ÀÌ¿ëÇÑ ÀÌÁß µðÁöÅÐ ½ºÄ³´×(double digital scanning) ±â¹ýÀÌ ÇÊ¿äÇÏ´Ù. ±¸³» ½ºÄµ ½Ã, ½ºÄµ ¹Ùµð¸¦ ¾ÈÁ¤ÀûÀÎ ·£µå¸¶Å©·Î ÀÌ¿ëÇÏ¸é ´ÙÁöÅÐ ÀλóÀÇ Á¤È®µµ Çâ»ó°ú ±â°ø°úÁ¤ÀÌ È¿À²ÀûÀÌ°í ´Ü¼øÈ­µÉ ¼ö ÀÖ´Ù. º» Áõ·Ê´Â ¿ÏÀü µðÁöÅÐ ½Ã½ºÅÛÀ» È°¿ëÇÏ¿© ¸ÂÃãÇü Ä¡°ú¿ë ÀÓÇöõÆ® Áö´ëÁÖ ¹× Àӽà º¸Ã¶¹°, ÃÖÁ¾ º¸Ã¶¹°À» °èȹÇÏ°í Á¦ÀÛÇÏ¿´´Ù. ÀÓÇöõÆ® ½Ä¸³ ÈÄ, ÀÓÇöõÆ®¿¡ ü°áÇÑ ±¸³» ½ºÄµ ¹Ùµð¿Í Àӽà ÀÇÄ¡ Á¶Á÷¸é¿¡ ÀÎ±â µÈ ±¸³» ½ºÄµ ¹ÙµðÀÇ ½ºÄµ ¿µ¿ªÀ» ÁßøÇÏ¿´´Ù. ÁßøµÈ ÆÄÀÏ¿¡¼­ Àӽà ÀÇÄ¡ÀÇ ¼öÁ÷ °í°æ¿¡ ¸Â´Â ¸ÂÃãÇü Ä¡°ú¿ë ÀÓÇöõÆ® Áö´ëÁÖ¿Í Àӽà º¸Ã¶¹°À» Á¦ÀÛÇÏ¿© ȯÀÚ¿¡°Ô ½ÃÀû ÇÏ¿´°í, Àӽà º¸Ã¶¹°À» Åä´ë·Î ÃÖÁ¾ º¸Ã¶¹°À» Á¦ÀÛÇÏ¿´´Ù. Àӽà ÀÇÄ¡ Á¦ÀÛ ½Ã ¼³Á¤ÇÑ ¼öÁ÷ °í°æ, Áß½ÉÀ§ µîÀ» ÃÖÁ¾ º¸Ã¶¹°±îÁö È°¿ëÇÏ¿© ±â´É ¹× ½É¹ÌÀûÀ¸·Î ¸¸Á·ÇÒ ¸¸ÇÑ °á°ú¸¦ ¾ò¾î À̸¦ º¸°íÇÏ°íÀÚ ÇÑ´Ù.

When restoring with a dental digital system for implant-supported prosthesis, a double digital scanning technique is required: an intraoral scan of the three-dimensional implant location and intraoral scan after placement of temporary denture or provisional prosthesis. During the intraoral scan, the use of scan body as a stable landmark can improve the accuracy of digital impression and simplify laboratory process. In this case, a full-digital system was used to plan and fabricate a custom abutment, provisional prosthesis, and definitive prosthesis. After implant placement, the scan area of the intraoral scan body connected with implant and the intraoral scan body marked on the inside of temporary denture were superimposed. Out of the superimposed files, a custom abutment and provisional prosthesis were fabricated which match the vertical dimension of temporary denture, and definitive prosthesis was fabricated based on provisional prosthesis. We report this case because result has been functionally and esthetically satisfactory by using vertical dimension and central relation set during the fabrication of temporary denture to the definitive prosthesis.

Å°¿öµå

ijµåÄ·; µðÁöÅÐ ½ºÄµ; ÀÓÇöõÆ® °íÁ¤¼º º¸Ã¶ ¼öº¹; ½ºÄµ ¹Ùµð
Computer aided design-computer aided manufacturing system (CAD-CAM); Digital scan; Implant-supported dental prosthesis; Scan body

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI
KoreaMed