Ultrasonic CleaningÀÌ Resin ÀÇÄ¡»óÀÇ ¾ÈÁ¤¿¡ ¹ÌÄ¡´Â ¿µÇâ¿¡ °üÇÑ ½ÇÇèÀû ¿¬±¸

´ëÇÑÄ¡°úÀÇ»çÇùȸÁö 1974³â 12±Ç 1È£ p.37 ~ 42
ÀÌÇѹ«,
¼Ò¼Ó »ó¼¼Á¤º¸
ÀÌÇѹ« ( Lee Han-Moo ) - ¼­¿ï´ëÇб³ ´ëÇпø Ä¡ÀÇÇаú º¸Ã¶ÇÐ

Abstract


To ascertain if the ultrasonic cleaning technique caused any dimensional changes in heat and cold curing and fluid resin denture bases and in addition to evaluate the dimensional changes of the resin denture bases stored in water and air, the author measured the distance between the outsides of two pins embedded in methyl methacrylate test denture bases by mean of 12 inch vernier caliper, accurate to 0.02mm. The results were as follows; (1) Ultrasonic cleaning didn¡¯t cause any permanent dimensional changes, but only affected temporary dimensional expansion in 16 test denture bases. (2) Temporary expansion rate caused by 10 minutes¡¯ ultrasonic cleaning was 0.29% and at the maximal temperature of the cleaning solution it was 0.64%. (3) The half of the denture bases stored in water showed the dimensional expansion rate of 0.47% while the others stored in air showed the dimensional shrinkage rate of 0.15% after 4 months.