Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

ÇÏ¾Ç Ä¡¹Ð°ñ °üÅë¹æ¹ýÀ¸·Î À̽ĽÃÀÇ ÀÀ·ÂºÐ»êÈ¿°ú¿¡ °üÇÑ À¯ÇÑ¿ä¼ÒºÐ¼®Àû ¿¬±¸

Effect of Stress Distribution of Mandibular Implant Bicortication Utilizing Finite Element Analysis Method

´ëÇÑÄ¡°úÀ̽ÄÇÐȸÁö 1996³â 15±Ç 1È£ p.86 ~ 102
À̾çÁø, ¾çÀçÈ£,
¼Ò¼Ó »ó¼¼Á¤º¸
À̾çÁø (  ) - ¼­¿ï´ëÇб³
¾çÀçÈ£ (  ) - ¼­¿ï´ëÇб³

Abstract


Dental implantation is a method restoring missing teeth, especially in the case of severely resorbed edentulous patient. But the direct contact between bone and implant surface, induces stress concentration to bone and eventually becomes a cause
of
failure in some cases.
@ES The results were as follows:
@EN 1.The stress concentration was more affected by the height of the mandible than implant length.

Å°¿öµå

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

  

µîÀçÀú³Î Á¤º¸