A comparison of conventional intraoral radiography and computer imaging techniques for the detection of proximal surface calculus

Ä¡°ú¹æ»ç¼± 1994³â 24±Ç 1È£ p.23 ~ 29
¼Ò¼Ó »ó¼¼Á¤º¸
°­º´Ã¶/Byung-Cheol Kang

Abstract

Àü³²´ëÇб³ Ä¡°ú´ëÇÐ ÇлýÀ» ´ë»óÀ¸·Î ÆòÇàÃÔ¿µ¹ýÀ¸·Î ÃÔ¿µÇÑ 168 ÀåÀÇ ±¸³»¹æ»ç¼±»çÁøÀ»
µðÁöÅ» ¿µ»óÀ¸·Î º¯È¯ÇÏ¿©, Çʸ§»óÀÇ Ä¡¼® À¯¹« Æǵ¶ °á°ú¿Í ¸ð´ÏÅÍ»óÀÇ Æǵ¶ °á°ú¸¦ ºñ±³
ÇÏ¿´´Ù. 3¸íÀÇ ±¸°­¾Ç¾È¸é¹æ»ç¼±ÇÐ Àü°ø Ä¡°úÀǻ簡 Æǵ¶À» Ç쵂 Çʸ§»óÀÇ Æǵ¶ °á°ú¸¦ ÆÇ
Á¤ÀÇ ±âÁØÀ¸·Î ÇÏ¿´´Ù. µðÁöÅ» ¿µ»óÀº »ó¾÷¿ë Çʸ§-ºñµð¿À º¯È¯ÀåÄ¡, 486DX PC, ±×¸®°í
PcVision°ú frame grabberÀ» ÀÌ¿ëÇÏ¿© ¾ò¾ú´Ù. ¸ð´ÏÅÍ»óÀÇ °³°³ ±¸³»¹æ»ç¼±»çÁø»óÀº 700¡¿
480 pixel·Î ³ªÅ¸³»¾ú´Ù. µðÁöÅ» ¿µ»óÀÇ Ä¡¼®Áø´ÜÀÇ sensitivity´Â 0.79 -0.90( Æò±Õ 0.86) ÀÌ
¾ú°í, specificity´Â 0.03-0.43( Æò±Õ 0.17) À̾ú´Ù.
#ÃÊ·Ï#
Intraoral radiographs are valuable in identifying calculus that intensify periodontal
disease especially for the proximal calculus.
With the advent of low cost, high performance computer, it became possible to
explore the use of digital image processing techniques on routine dental X-ray images.
There are already several digital radiographic systems, HVG(RadioVisioGraphy) by
Trophy Radiology (Atlanta, GA, USA), Sens-A-Ray by Regam Medical Systems(AB,
Sundsvall, Sweden), Vixa(Visualix) by the Gendex Corporation(Milwakee, WI, USA),and
Flash Dent by Villa Sistemi Medicali (Bucciasco, Italy).
Hidebot et at introduced four general-purpose image processing programs for the
Apple Macintosh ¥± computer.
Ann Wenzel and his coworker in paris reported that in detecting the occlusal caries,
digital images from RVG is somewhat superior to the conventional radiographs.
Most oral radiologist employ film images that are interpreted on a lightbox or view
box. We dentist are accustomed to the conventional film radiographs. But I think we
must use the digital images for diagnosis of oral and maxillofacial diseases in near
future. Now we have to adjust ourselves to the digital imaging on the monitor. And we
are needed the ability to transfer film based reading skills to a digitally based
presentation. And we also needed 13 building confidence in digital images and to
familiar with the digital images.
The aim of present investigation is to suggest economical hybrid system using
personal computer and to compare the periapical radiographs and their displayed digital
images for proximal calculus detection.