3Á¾ÀÇ ÀÚ°¡ºÎ½Ä ÇÁ¶óÀ̸ÓÀÇ »ó¾ÆÁú°è¸é Á¢ÃË°¢ ¹× ¹Ì¼¼ÀÎÀå°áÇÕ°­µµ¿¡ °üÇÑ ¿¬±¸

Measurement of Contact Angle and Bond Strength Using 3 Different Self-Etching Primer

Àå¼®¿ì, ±ÇÈ£¹ü, À¯Çö¹Ì, ¹Úµ¿¼º, ¿Àż®, ¹è±¤½Ä,
¼Ò¼Ó »ó¼¼Á¤º¸
Àå¼®¿ì ( Chang Seok-Woo ) - ¼º±Õ°ü´ëÇб³
±ÇÈ£¹ü ( Kwon Ho-Beom ) - ¼º±Õ°ü´ëÇб³
À¯Çö¹Ì ( Yoo Heyon-Mee ) - ¼º±Õ°ü´ëÇб³
¹Úµ¿¼º ( Park Dong-Sung ) - ¼º±Õ°ü´ëÇб³
¿Àż® ( Oh Tae-Seok ) - ¼º±Õ°ü´ëÇб³
¹è±¤½Ä ( Bae Kwang-Shik ) - ¼­¿ï´ëÇб³

Abstract

º» ¿¬±¸ÀÇ ¸ñÀûÀº 3Á¾ÀÇ ÀÚ°¡ºÎ½Ä ÇÁ¶óÀ̸Ó(Clearfil SE Bond, AdheSE, Tyrian) »ç¿ë½Ã »ó¾ÆÁú°è¸éÀÇ Á¢ÃË°¢ ¹× ¹Ì¼¼ÀÎÀå°áÇÕ°­µµ¸¦ ÃøÁ¤ÇÏ´Â °ÍÀÌ´Ù. ¿¬¸¶µÈ »ó¾ÆÁú Ç¥¸é¿¡ 3Á¾ÀÇ ÀÚ°¡ºÎ½Ä ÇÁ¶óÀ̸Ӹ¦ °¢°¢ Àû¿ëÇÑ ÈÄ Á¢ÃË°¢À» ÃøÁ¤ÇÏ¿´À¸¸ç (n=30), One-way ANOVA¸¦ »ç¿ëÇÏ¿© Åë°èó¸®ÇÏ¿´´Ù. ¹Ì¼¼ÀÎÀå°áÇÕ°­µµÃøÁ¤À» À§Çؼ­´Â »ó¾ÆÁú Ç¥¸é¿¡ 3Á¾ÀÇ ÀÚ°¡ºÎ½Ä ÇÁ¶óÀÌ¸Ó ¹× »ó¾ÆÁú Á¢ÂøÁ¦¸¦ °¢°¢ Àû¿ëÇÑ ÈÄ ±¤ÁßÇÕ º¹ÇÕ·¹Áø (Z 250)À» 5mm µÎ²²·Î ½×¾Æ ¿Ã·È´Ù. ±× ÈÄ °¢ ½ÃÆíÀ» °áÇÕ°è¸é¿¡ ¼öÁ÷À¸·Î ºÐÇÒÇÑ µÚ (n=45) universal testing machineÀ» »ç¿ëÇÏ¿© ¹Ì¼¼ÀÎÀå°­µµ¸¦ ÃøÁ¤ÇÏ¿´°í , Kruskal-Wallis test¸¦ ÅëÇÏ¿© Åë°èó¸®ÇÏ¿´´Ù. Á¢ÃË°¢ ÃøÁ¤°á°ú, AdheSE, Clearfil SE Bond, Tyrian ¼øÀ¸·Î ³ôÀº Á¢ÃË°¢À» º¸¿´À¸¸ç °¢ ±º°£ Åë°èÀû À¯ÀǼº ÀÖ´Â Â÷À̸¦ º¸¿´´Ù (p<0.05). ¹Ì¼¼ÀÎÀå°áÇÕ°­µµ ÃøÁ¤°á°ú Clearfil SE Bond±º°ú AdheSE±ºÀº À¯ÀǼº ÀÖ´Â Â÷À̸¦ º¸ÀÌÁö ¾Ê¾ÒÀ¸¸ç, Tyrian±ºÀº Clearfil SE Bond ±ºÀ̳ª AdheSE ±º¿¡ ºñÇØ À¯ÀǼº ÀÖ°Ô ÀÛÀº ¹Ì¼¼ÀÎÀå°áÇÕ°­µµ¸¦ º¸¿´´Ù.

The purpose of this study was to evaluate the contact angle made by 3 kinds of self etching primers (Clearfil SE Bond, AdheSE, and Tyrian) on dentin and to measure the microtensile bond strength of resin composite to dentin using these self-etching primers. Contact angle between each of 3 self etching primers and polished dentin surface was measured (n=30) by contact angle analyzer and the result was analyzed by One-way ANOVA. For the measurement of microtensile bond strength, polished dentin surface was treated with each of 3 self etching primers and dentin adhesives. Z-250 composite resin was built-up with a height of 5 mm on the adhesive-treated surface and light cured for 40s with a halogen light curing unit. Thereafter, each tooth was sectioned into slabs perpendicular to the bonded interface and trimmed (n=45). The microtensile bond strength was measured with universal testing machine and the result was analyzed with Kruskal-Wallis test. AdheSE group showed the highest contact angle followed by Clearfil SE group and Tyrian group (p<0.05). AdheSE group and Clearfil SE group showed significantly higher microtensile bond strength than Tyrian group (P<0.05).

Å°¿öµå

¹Ì¼¼ÀÎÀå°áÇÕ°­µµ;»ó¾ÆÁú Á¢Âø°è¸é;ÀÚ°¡ºÎ½Ä ÇÁ¶óÀ̸Ó;Á¢ÃË°¢Measurement of contact angle and bond strength using 3 different self-etching primer