Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

ÀÓÇöõÆ® Áö´ëÁÖ ÇüÅÂ¿Í ½Ã¸àÆ® Á¾·ù¿¡ µû¸¥ ÀüºÎÁÖÁ¶±Ý°üÀÇ À¯Áö·Â ºñ±³

The Comparison of the retention of the full veneer casted gold crowns with different implant abutment shapes and types of cements

Á¤Àç¿í, ±èÁöȯ, ±è¼±Àç, ¹®È«¼®, ½ÉÁؼº,
¼Ò¼Ó »ó¼¼Á¤º¸
Á¤Àç¿í ( Jung Jae-Wook ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ º¸Ã¶°úÇб³½Ç
±èÁöȯ ( Kim Jee-Hwan ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ º¸Ã¶Çб³½Ç
±è¼±Àç ( Kim Sun-Jai ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ º¸Ã¶°úÇб³½Ç
¹®È«¼® ( Moon Hong-Seok ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ º¸Ã¶°úÇб³½Ç
½ÉÁؼº ( Shim June-Sung ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ º¸Ã¶Çб³½Ç

Abstract

º» ¿¬±¸¿¡¼­´Â ½Ã¸àÆ® À¯ÁöÇü ÀÓÇöõÆ®¿¡¼­ Áö´ëÁÖÀÇ ¼ö·Å°¢°ú ½Ã¸àÆ® Á¾·ù¿¡ µû¶ó º¸Ã¶¹°ÀÇ À¯Áö·Â¿¡ ¹ÌÄ¡´Â ¿µÇâ¿¡ ´ëÇØ ¾Ë¾Æº¸°íÀÚ ÇÏ¿´´Ù. ÀÓÇöõÆ® Áö´ëÁÖ¿Í À¯»çÇÑ ¿ÜÇüÀ» °®´Â ±Ý¼Ó ´ÙÀ̸¦ Á¦ÀÛÇÏ¿´À¸¸ç, ªÀº Áö´ëÁÖ(5mm)¿Í ±ä Áö´ëÁÖ(10mm) µÎ°¡Áö·Î ¼³Á¤ÇÏ¿´À¸¸ç, °¢°¢ 5, 10, 15, 25µµÀÇ ¼ö·Å°¢À» °®´Â ±Ý¼Ó ´ÙÀ̸¦ Á¦ÀÛÇÏ¿´´Ù. ±Ý¼Ó ´ÙÀÌ¿Í ±Ý¼Ó ´ÙÀ̷κÎÅÍ Á¦ÀÛÇÑ ±ÝÁÖÁ¶°üÀ» Temp-bond, petroleum jelly¸¦ ÀÏÁ¤ ºñÀ²·Î ¼¯Àº Temp-bond, ZPC, Premier implant cement·Î ÇÕÂø½ÃŲ ÈÄ, ÀÎÀå·Â¿¡ ´ëÇÑ À¯Áö·ÂÀ» ÃøÁ¤ÇÏ¿´´Ù. ±× ÈÄ °¢°¢ÀÇ ½Ã¸àÆ® ±º¿¡¼­ ¼ö·Å°¢ÀÇ º¯È­°¡ À¯Áö·Â¿¡ ¹ÌÄ¡´Â ¿µÇâ°ú °¢ ¼ö·Å°¢ ±º¿¡¼­ ½Ã¸àÆ®ÀÇ º¯È­°¡ À¯Áö·Â¿¡ ¹ÌÄ¡´Â ¿µÇâÀ» ºñ±³ÇÏ¿´´Ù. ¶ÇÇÑ º» ½ÇÇè¿¡¼­ »ç¿ëµÈ ½Ã¸àÆ® Áß Premier implant cementÀÇ º¯¿¬ °£°Ý¿¡ ´ëÇÑ ¿¬±¸¸¦ Ãß°¡ÀûÀ¸·Î ½ÃÇàÇÏ¿´À¸¸ç, in-vitro ½ÇÇèÀÇ ÇÑ°è ³»¿¡¼­ ´ÙÀ½°ú °°Àº °á·ÐÀ» µµÃâÇÏ¿´´Ù. 1. Petroleum jelly¸¦ ÷°¡ÇÑ Temp-bondÀÇ °æ¿ì °¢°¢ ¼ö·Å°¢ÀÌ Áõ°¡ÇÔ¿¡ µû¶ó ¸ðµç °æ¿ì¿¡ À¯Áö·ÂÀÌ °¨¼ÒÇÔÀ» º¸¿´À¸¸ç, ½Ã¸àÆ® Áß °¡Àå ³·Àº À¯Áö·ÂÀ» ³ªÅ¸³Â´Ù. 2. ZPCÀÇ °æ¿ì ¼ö·Å°¢ÀÌ Áõ°¡ÇÔ¿¡ µû¶ó À¯Áö·ÂÀÇ °¨¼Ò¸¦ º¸¿´À¸¸ç, ¼ö·Å°¢ÀÌ 5µµÀÎ °æ¿ì ZPC°¡ Premier implant cementº¸´Ù ´õ Å« À¯Áö·ÂÀ» º¸¿´´Ù. 3. Premier implant cementÀÇ °æ¿ì ¼ö·Å°¢ÀÌ 5µµÀÏ ¶§ °¡Àå ÀÛÀº À¯Áö·ÂÀ» º¸ÀÌ°í 10µµ¿¡¼­ °¡Àå Å« °ªÀ» º¸ÀÎ ÈÄ ¼ö·Å°¢ÀÌ Áõ°¡ÇÒ¼ö·Ï À¯Áö·ÂÀÌ °¨¼ÒÇÏ´Â ¾ç»óÀ» º¸¿´´Ù. 4. Premier implant cementÀÇ °æ¿ì À̹ø ½ÇÇèÀÇ Á¶°Ç ³»¿¡¼­ ¼ö·Å°¢ÀÌ 10µµÀÏ ¶§º¸´Ù 5µµÀÏ ¶§ ´õ Å« º¯¿¬ °£°ÝÀ» º¸¿´´Ù.

The purpose of the study is to establish the effect of different abutment shapes and types of cements on the retention of the full veneer casted gold crowns. Metal dies that has the similar shape with the implant abutment were manufactured using a short(5mm) and long(10mm) dies with different convergence angles. Metal dies and gold crowns, which were made from the metal dies, were cemented with Temp-bond, Temp-bond mixed with petroleum jelly, ZPC and Premier implant cement. After that, these were tested for tensile force at the point of separation. The effect of convergence angle changes of different cement types on the retention was studied as well as the effects of the cement type changes with different convergence angles on the retention. In addition, study about the marginal gap of Premier implant cement used for this experiment was conducted. The results are as followed under the in-vitro experimental limits; 1. The retention of the Temp-bond mixed with petroleum jelly decreased as the convergence angle increased, and the retention was weakest among the cements. 2. The retention of ZPC decreased as convergence angle increased. When convergence angle was 5 degrees, ZPC showed stronger retention than Premier implant cement. 3. Premier implant cement had the weakest retention when the convergence angle was 5 degrees but when the convergence angle was 10 degrees, it had the strongest retention. As the angle increased more than 10 degrees, the retention decreased. 4. Premier implant cement showed bigger marginal gap when the convergence angle was 5 degrees than 10 degrees under the experimental condition.

Å°¿öµå

¼ö·Å°¢;Áö´ëÁÖ ±æÀÌ;Ä¡°ú¿ë ÀÓÇöõÆ® ½Ã¸àÆ®;À¯Áö·Â;ÀÎÀå·Â;±Ý¼Ó ´ÙÀÌ
Convergence angle;abutment length;dental implant cement;retention;tensile force;metal die

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

µîÀçÀú³Î Á¤º¸

KCI