Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

ÀÇÄ¡»ó ·¹Áø °­È­Àç°¡ ÀÇÄ¡»ó ±ÁÈû°­µµ¿¡ ¹ÌÄ¡´Â ¿µÇâ

The Effect of Reinforcing Materials on the Transverse Strength of Denture Base Resin

±¸°­È¸º¹ÀÀ¿ë°úÇÐÁö 2012³â 28±Ç 4È£ p.327 ~ 337
ÀÌÁؽÄ, ¼Û¿µ±Õ, Á¶ÀÎÈ£,
¼Ò¼Ó »ó¼¼Á¤º¸
ÀÌÁؽĠ( Lee Jun-Sik ) - ´Ü±¹´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úº¸Ã¶Çб³½Ç
¼Û¿µ±Õ ( Song Young-Gyun ) - ´Ü±¹´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úº¸Ã¶Çб³½Ç
Á¶ÀÎÈ£ ( Cho In-Ho ) - ´Ü±¹´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úº¸Ã¶Çб³½Ç

Abstract

º» ¿¬±¸¿¡¼­´Â ±¤ÁßÇÕÇü ¼®¿µ ¼¶À¯ÀÎQuarts SplintTM Mesh¸¦ Áß½ÉÀ¸·Î ´Ù¾çÇÑ °­È­ÀçÀÇ ÀÇÄ¡»ó º¸°­ È¿°ú¿¡ ´ëÇØ ¾Ë¾Æº¸°íÀÚ ÇÏ¿´´Ù. ÀÇÄ¡»ó ·¹ÁøÀ¸·Î Lucitone199¨Þ¿Í QC-20À» »ç¿ëÇÏ¿´À¸¸ç °­È­Àç·Î Æú¸®¿¡Æ¿·» ¼¶À¯ÀÎ Ribbond¨Þ, Quarts SplintTM Mesh, ±Ý¼Ó °ÝÀÚ °­È­À縦 »ç¿ëÇÏ¿´´Ù. 2.0¡¿10.0¡¿65.0 mm ½ÃÆíÀ» °¢°¢ 10°³¾¿ Á¦ÀÛÇÏ¿´À¸¸ç 2.5¡¿10.0¡¿65.0 mm, 3.0¡¿10.0¡¿65.0 mm ½ÃÆíµµ Á¦ÀÛÇÏ¿´´Ù. Lucitone199¨Þ ·¹ÁøÀº QC-20 ·¹Áøº¸´Ù ³ôÀº ±ÁÈû°­µµ¸¦ ³ªÅ¸³»¾úÀ¸¸ç, ´ëÁ¶±º¿¡¼­ À¯ÀÇÂ÷¸¦ ³ªÅ¸³»¾ú´Ù(p<0.05). Lucitone199¨Þ ¹× QC-20 ·¹ÁøÀ¸·Î Á¦ÀÛÇÑ 2.0 mm µÎ²² ½ÃÆí¿¡¼­ ±ÁÈû°­µµ´Â ±Ý¼Ó °ÝÀÚ °­È­Àç, Quarts SplintTM Mesh, Ribbond¨Þ, ´ëÁ¶±º ¼øÀ¸·Î °¨¼ÒµÇ¾ú´Ù. Lucitone199¨Þ ·¹ÁøÀ» ÀÌ¿ëÇÏ¿© Á¦ÀÛÇÑ µÎ²² 2.0 mm, 2.5 mm ½ÃÆí¿¡¼­ Quarts SplintTM Mesh·Î º¸°­ÇÑ ±ºÀº ´ëÁ¶±ºº¸´Ù À¯ÀÇÇÏ°Ô ³ôÀº ±ÁÈû°­µµ¸¦ ³ªÅ¸³»¾úÀ¸¸ç(p<0.05), µÎ²² 3.0 mm ½ÃÆí¿¡¼­´Â À¯ÀÇÂ÷°¡ ¾ø¾ú´Ù.

The object of this study was to find out the effect of various reinforcing materials including Quarts SplintTM Mesh on
the transverse strength of the denture resin. QC-20 and Lucitone199¨Þ were used as the denture resin, and polyethylene
fiber Ribbond¨Þ, light curing quarts fiber Quarts SplintTM Mesh, metal mesh were used as the reinforcing materials. Ten
specimens were fabricated for each group and the size of specimens was 2.0¡¿10.0¡¿65.0 mm. To compare the effect of
resin thickness, additional specimens of 2.5¡¿10.0¡¿65.0 mm, 3.0¡¿10.0¡¿65.0 mm were fabricated. In the control group,
the transverse strength of Lucitone199¨Þ was significantly higher than that of QC-20(p<0.05). Among the specimens of 2.0
mm thickness fabricated with Lucitone199¨Þ and QC-20, they showed high transverse strength in the order of metal mesh,
Quarts SplintTM Mesh, Ribbond¨Þ, and control group. In the specimens of 2.0 mm, 2.5 mm thickness, the transverse strength of Quarts SplintTM Mesh were significantly higher than that of QC-20(p<0.05). But in the specimens of 3.0 mm thickness, there was no significant difference.

Å°¿öµå

ÀÇÄ¡»ó;°­È­Àç;Quarts SplintTM Mesh;±ÁÈû°­µµ
Denture base resin;Reinforcing materials;Quarts SplintTM Mesh;Transverse strength