Comparing the efficiency of periodontal instrument sharpening using aluminum oxide stones with different levels of roughness

±¸°­È¸º¹ÀÀ¿ë°úÇÐÁö 2014³â 30±Ç 2È£ p.131 ~ 137
±è¿ë°Ç,
¼Ò¼Ó »ó¼¼Á¤º¸
±è¿ë°Ç ( Kim Yong-Gun ) - °æºÏ´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡ÁÖ°úÇб³½Ç

Abstract

¸ñÀû: ÀÌ ¿¬±¸´Â ´Ù¾çÇÑ °ÅÄ¥±â¸¦ °¡Áø ¾Ë·ç¹Ì´½ ¿Á»çÀÌµå ¿¬¸¶¼®À¸·Î Ä¡Áֱⱸ ³¯ ¼¼¿ì±â¸¦ ½ÃÇà½Ã ¿¬¸¶¼®ÀÇ °ÅÄ¥±â¿¡ µû¸¥ Ä¡Áֱⱸ ³¯ ¼¼¿ì±âÀÇ È¿À²¼º ¹× ¸¶¸ðµµ¸¦ ºñ±³ Æò°¡ÇÏ¿´´Ù.

¿¬±¸ Àç·á ¹× ¹æ¹ý: 30°³ÀÇ No. 9 - 10 ±×·¹À̽à ť·¿ÀÌ »ç¿ëµÇ¾ú°í, ¸ðµç Å¥·¿Àº Ä¡¼®Á¦°Å¼ú ¹× Ä¡±ÙÈ°ÅüúÀ» ½ÃÇàÇÔÀ¸·Î½á ³¯À» ¹«µð°Ô ¸¸µé°í 3°¡Áö ±×·ì(240, 600, 800 grit)À¸·Î ÀÓÀÇ·Î ³ª´©¾ú´Ù. Ä¡ÁֱⱸÀÇ ¿¹¹Îµµ´Â ¿¬¸¶¼®À» ÃÖ´ë 20ȸ ±â±¸¿¡ Àû¿ëÇÑ ÈÄ Æò°¡µÇ¾ú°í, ¸¶¸ðµµ´Â ÃÖ´ë 80ȸ ÈÄ ±â±¸ ³¯ÀÇ ³¡ 1 mm¿Í 2 mm¿¡¼­ ±â±¸ ³¯ÀÇ ÆøÀ¸·Î Æò°¡µÇ¾ú´Ù.

°á°ú: Ä¡Áֱⱸ ¿¹¹Îµµ´Â 5ȸ¿Í 10ȸ »óÇÏ ¿îµ¿½Ã 240 grit¿¡¼­ À¯ÀÇÇÏ°Ô ³ô°Ô ³ªÅ¸³µÀ¸¸ç(P < 0.001), 15ȸ, 20ȸ¿¡¼­´Â À¯ÀÇÇÑ Â÷ÀÌ´Â ¾ø¾ú´Ù(P > 0.05). ¸¶¸ðµµ´Â 240 gritÀÇ °æ¿ì 600 grit°ú 800 grit¿¡ ºñÇØ ¾à°£ ³ô°Ô ³ªÅ¸³µÁö¸¸ Åë°èÀû À¯ÀǼºÀº ¾ø¾ú´Ù.

°á·Ð: ¾Ë·ç¹Ì´½ ¿Á»çÀÌµå ¿¬¸¶¼®ÀÇ ÀÔÀÚ°¡ Ŭ¼ö·Ï Ä¡Áֱⱸ ³¯ ¼¼¿ì±âÀÇ È¿À²¼ºÀº Áõ°¡ÇÏ¿´´Ù. ÇÏÁö¸¸ ±â±¸ÀÇ ¸¶¸ð¿¡ À¯ÀÇÇØ¾ß ÇÑ´Ù.

Purpose: This study examined the efficiency and wear of periodontal instrument sharpening using aluminum oxide stones with different levels of roughness.

Materials and Methods: Thirty new No. 9-10 Gracey curets were used in this study. All curets had become dull after scaling and root planing. After similar blunting, the instruments were divided randomly into three groups (240, 600, 800 grit) containing 10 curets each. The stones were applied correctly to the lateral surface of each curet to maintain the 70-80¡Æ angle. After resharpening, sharpness of the curets was examined by an optical microscope. After 20, 40, 60, and 80 strokes, the wear was measured at 1 mm and 2 mm from the tip of the cutting edge using a digital caliper. The data was analyzed statistically using analysis of variance (ANOVA) with repeated measures, 2-way ANOVA, and a Fisher¡¯s exact test.

Results: The degree of sharpness increased significantly (P < 0.001) as the number of sharpening strokes grew for all stones. A comparison of the degree of sharpness on the same number of strokes showed that the 240 grit group significantly excelled the other groups on 5 and 10 strokes, respectively (P < 0.001). The mean wear showed no statistically significant difference among the groups (P > 0.05).

Conclusion: The efficiency of Gracey curet resharpening was enhanced with more coarse stones, though we should consider the wear of the instrument during resharpening.

Å°¿öµå

¾Ë·ç¹Ì´½ ¿Á»çÀÌµå ¿¬¸¶¼®;Ä¡Áֱⱸ ³¯ ¼¼¿ì±â;¿¹¹Îµµ;¸¶¸ðµµ
aluminum oxide stone;periodontal sharpening;sharpness;wear