Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

ÀÌ¿ø ÁßÇÕ ·¹Áø½Ã¸àÆ®ÀÇ ¼öºÐ ÈíÂøµµ¿Í ¼öºÐ ÈíÂø¿¡ µû¸¥ °æµµ º¯È­ ºñ±³ ¿¬±¸

A study on the water sorption and the effect of water sorption on micro-hardness of dual-cure resin cements

±¸°­È¸º¹ÀÀ¿ë°úÇÐÁö 2014³â 30±Ç 2È£ p.138 ~ 144
ÃÖ¼öÁ¤, Á¶ÁøÇö, ÀÌûÈñ,
¼Ò¼Ó »ó¼¼Á¤º¸
ÃÖ¼öÁ¤ ( Choi Su-Jung ) - °æºÏ´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç
Á¶ÁøÇö ( Cho Jin-Hyun ) - °æºÏ´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç
ÀÌûÈñ ( Lee Cheong-Hee ) - °æºÏ´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç

Abstract

¸ñÀû: ÀÌ ¿¬±¸ÀÇ ¸ñÀûÀº ´Ù¾çÇÑ ÀÌ¿ø ÁßÇÕ ·¹Áø ½Ã¸àÆ®ÀÇ ¼öºÐ ÈíÂøµµ¸¦ Á¶»çÇÏ°í, ¼öºÐ ÈíÂø¿¡ µû¸¥ ¹Ì¼¼ °æµµ º¯È­¸¦
ºñ±³Çغ¸´Â °ÍÀÌ´Ù.

¿¬±¸ Àç·á ¹× ¹æ¹ý: ´Ù¼¸ °¡ÁöÀÇ ÀÌ¿øÁßÇÕ ·¹Áø½Ã¸àÆ®¸¦ ¼±Á¤ÇÏ¿´´Ù(Maxcem, Duo-link, Panavia F, Variolink¥±, Rely X Unicem). °¢ ±×·ì ´ç 10°³¾¿, ÃÑ 50°³ÀÇ ½ÃÆíÀ» Á¦ÀÛÇÏ¿´´Ù.°¢ ±×·ì ´ç 5°³ÀÇ ½ÃÆíµéÀ» Áõ·ù¼ö¿¡ 7ÀÏ µ¿¾È º¸°ü ÈÄ ¼öºÐ
ÈíÂøµµ¸¦ Æò°¡ÇÏ¿´´Ù. Áõ·ù¼ö¿¡ º¸°üÇÑ ½ÃÆí°ú º¸°üÇÏÁö ¾ÊÀº ½ÃÆíµéÀ» ºñ±³ÇÏ¿© °á°ú¸¦ ¾ò¾ú´Ù.

°á°ú: 1. ¼öºÐ ÈíÂøµµ¿¡ À־ MaxcemÀÌ À¯ÀǼº ÀÖ°Ô °¡Àå ³ô¾Ò´Ù. 2. Áõ·ù¼ö¿¡ º¸°üÇÏÁö ¾Ê¾Ò´ø ½ÃÆíÀÇ ¹Ì¼¼ °æµµ´Â Rely X UnicemÀÇ À¯ÀǼº ÀÖ°Ô °¡Àå ³ô¾Ò´Ù. 3. Áõ·ù¼ö¿¡ º¸°üÇÏ¿´´ø ½ÃÆíÀÇ ¹Ì¼¼ °æµµ´Â Rely X UnicemÀÌ À¯ÀǼº ÀÖ°Ô °¡Àå ³ô¾Ò´Ù. 4. ¼öºÐ Èí¼ö¿¡ µû¸¥ ¹Ì¼¼ °æµµÀÇ º¯È­¿¡ À־ Variolink¥±´ÂÂ÷ÀÌ°¡¾ø´Â°ÍÀ¸·Î³ªÅ¸³µÀ¸³ª, Duo-link, Panavia F, ±×¸®°í Rely X UnicemÀº °¨¼ÒµÇ¾úÀ¸¸ç, MaxcemÀº Áõ°¡µÇ¾ú´Ù.

°á·Ð: ÀÓ»óÀûÀ¸·Î ·¹Áø½Ã¸àÆ® ¼±Åýà ¼öºÐ ÈíÂøµµ°¡ ÀÛ°í, ¹Ì¼¼ °æµµ°¡ ³ôÀº Àç·á¸¦ ¼±ÅÃÇÏ´Â °ÍÀÌ ÃßõµÈ´Ù.

Purpose: This study examined the water sorption of commonly used dual-cure resin cements and compared the change in the micro-hardness among the cements.

Materials and Methods: Five types of dual-cure resin cements (Maxcem, Duo-link, Panavia F, Variolink II, Rely X Unicem) were selected. Fifty specimens were classified into five groups containing ten specimens in each group. The water sorption of the five specimens in each group was evaluated after being immersed in distilled water (DDW) for seven days.
The following results were obtained by comparing the specimens immersed in DDW with those not immersed in DDW.

Results: 1. The water sorption of Maxcem showed the highest score, followed by Panavia F. These two cements were followed by Duo-link and Rely X Unicem. The water sorption of Variolink II showed the lowest score among the cements used in this study. 2. Among the specimens not immersed in DDW, the micro-hardness of Rely X Unicem showed the highest score followed by Panavia F and Variolink II. These cements were followed in order by Duo-link and Maxcem. 3. Among the specimens immersed in DDW, the microhardness of Rely X Unicem showed the highest score followed by Maxcem, Panavia F and Variolink II. Duo-link shoed the lowest score among the cements used in this study. 4. Maxcem, Duo-link, Panavia F and Rely X Unicem showed significant differences in micro-hardness due to water resorption but Variolink II was unaffected by immersion in water.

Conclusion: Using the resin cement which has lower water sorption and higher micro-hardness is recommended.

Å°¿öµå

ÀÌ¿øÁßÇÕ·¹Áø½Ã¸àÆ®;°æµµ
dual-cure resin cement;hardness

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI