¾ËÁö³×ÀÌÆ® Àλóü¿¡¼­ Á¦ÀÛµÈ Ä¡°ú¿ë ¼®°í ¸ðÇüÀÇ Á¤È®µµ¿¡ ´ëÇÑ »ïÂ÷¿ø µðÁöÅÐ ºÐ¼®

Three dimensional accuracy analysis of dental stone casts fabricated using irreversible hydrocolloid impressions

±¸°­È¸º¹ÀÀ¿ë°úÇÐÁö 2015³â 31±Ç 4È£ p.316 ~ 328
¼Ò¼Ó »ó¼¼Á¤º¸
ÁÖ¿ëÈÆ:Joo Young-Hun ÀÌÁøÇÑ:Lee Jin-Han

Abstract

¸ñÀû: º¸°ü Á¶°Ç°ú ¼®°í ÁÖÀÔ ½Ã°£¿¡ µû¶ó ¾ËÁö³×ÀÌÆ® Àλóü·ÎºÎÅÍ Á¦ÀÛµÈ ¸ðÇüÀÇ Á¤È®¼ºÀ» ¾Ë¾Æº¸°íÀÚ ÇÏ¿´´Ù.

¿¬±¸ Àç·á ¹× ¹æ¹ý: äµæµÈ ¾ËÁö³×ÀÌÆ® Àλóü´Â ½Àµµ°¡ À¯ÁöµÇ´Â Ç×½ÀÁ¶¿¡ º¸°üÇÏ´Â °Í°ú Áø·á½Ç ³»ÀÇ °ø±â Áß¿¡ ³ëÃâµÇ´Â »óÅ·Πº¸°ü Á¶°ÇÀ» ´Þ¸®ÇÏ¿´´Ù. º¸°ü Á¶°Ç¿¡ µû¶ó °¢°¢ Áï½Ã, äµæµÈ ÈÄ 10ºÐ, 30ºÐ, 180ºÐ, 360ºÐÀ¸·Î ³ª´©¾î º¸°üÇÑ ÈÄ¿¡ ¼®°í ¸ðÇüÀ» Á¦ÀÛÇÏ¿´´Ù. Á¦ÀÛµÈ ¼®°í ¸ðÇüÀ» 3D ·¹ÀÌÀú ½ºÄ³³Ê·Î »ïÂ÷¿ø µðÁöÅÐ ¸ðÇüÀ» ±¸¼ºÇÏ¿´°í ±¸¼ºµÈ µðÁöÅÐ ¸ðÇüÀÇ Âü°íÁ¡¿¡¼­ °Å¸®¸¦ ÃøÁ¤ÇÏ¿© º¯Çü·üÀ» ºñ±³ÇÏ¿´´Ù. ¶ÇÇÑ °¢ ½ÇÇ豺ÀÇ »ïÂ÷¿ø µðÁöÅÐ Æò±Õ ¸ðÇüÀ» Á¦ÀÛÇÑ ÈÄ ÁßøÀ» ½ÃÇàÇÔÀ¸·Î½á Ç¥¸é º¯À§°¡ ¹ß»ýÇÑ ºÎÀ§¿Í Å©±â¸¦ È®ÀÎÇÏ¿´´Ù.

°á°ú: Àλó äµæ Áï½Ã Á¦ÀÛÇÑ ¸ðÇüÀÇ º¯Çü·üÀÌ °¡Àå ÀÛ°Ô ³ªÅ¸³µ°í, °ø±â Áß¿¡ º¸°üÇÑ Àλóüº¸´Ù Ç×½ÀÁ¶¿¡ º¸°üÇÑ ÀλóüÀÇ º¯Çü·üÀÌ ÀÛ°Ô ³ªÅ¸³µ´Ù. ¼®°í ÁÖÀÔ ½Ã°£ÀÌ Áõ°¡ÇÔ¿¡ µû¶ó¼­ º¯Çü·üµµ Áõ°¡ÇÏ¿´À¸¸ç, ¼®°í ÁÖÀÔ ½Ã°£ÀÌ 180ºÐÀ» Áö³ª¸é º¸°ü Á¶°Ç¿¡ °ü°è¾øÀÌ ´ë±¸Ä¡ ºÎÀ§¿¡¼­ º¯Çü·ü°ú Ç¥¸é º¯À§°¡ Áõ°¡ÇÑ´Ù.

°á·Ð: ¾ËÁö³×ÀÌÆ® Àλóü·ÎºÎÅÍ Á¦ÀÛµÈ ¸ðÇüÀÇ Á¤È®¼ºÀ» À§Çؼ­´Â Àλó äµæ ÈÄ, Áï½Ã ¸ðÇüÀ» Á¦ÀÛÇØ¾ß ÇÑ´Ù. º¸°üÀÌ ÇÊ¿äÇÑ °æ¿ì¿¡´Â 100% »ó´ë½Àµµ°¡ À¯ÁöµÇ´Â Ç×½ÀÁ¶¸¦ ÀÌ¿ëÇÏ°í, º¸°ü ½Ã°£Àº 180ºÐÀ» ³ÑÁö ¾Êµµ·Ï ÇØ¾ß Á¤È®ÇÑ ¸ðÇüÀ» ¾òÀ» ¼ö ÀÖ´Ù.

Purpose: The objects of this study was to evaluate the accuracy of the dental stone casts made from alginate impressions according to storage condition and stone pouring time.

Materials and Methods: Each of upper and lower impressions of dental model was taken. The dental stone models were made immediately, 10, 30, 60, 180, 360 minutes after the impressions were taken at each storage condition. 3D models were constructed by scanning the stone model using 3D laser scanner. With Reference points, positioned on digital models, linear measurements of the dimensional change were compared by 3D metrology software, 3D average models were made and superimposition to identify the specific site of dimensional change and to measure surface deviation (mm).

Results: Dental stone models which were made immediately after taking the impression showed the smallest linear dimensional change. As the stone pouring time was prolonged, the linear dimensional change was increased. More than 180 minutes after impression taking, linear dimensional change and surface distortion increased in the posterior molar region, regardless of the storage condition.

Conclusion: For the optimum accuracy of the dental stone casts, alginate impression should be poured as soon as possible. If there were a need for storing, a humidor with 100% relative humidity must be used and be stored less than 180 minutes to fabricate the accurate dental model.

Å°¿öµå

¾ËÁö³×ÀÌÆ® Àλóü; üÀû¾ÈÁ¤¼º; »ïÂ÷¿ø Áßø
alginate impression; dimensional stability; 3D superimposition

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI