Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

¿©·¯ º¹ÇÕ·¹Áø¿¡¼­ ¼öºÐ Èí¼ö¿¡ ÀÇÇÑ »öº¯È­¿¡ ¿¬¸¶°¡ ¹ÌÄ¡´Â ¿µÇâ

Effect of polishing methods on color change by water absorption in several composite resins

±¸°­È¸º¹ÀÀ¿ë°úÇÐÁö 2019³â 35±Ç 1È£ p.1 ~ 10
±èÇýÁø, ±è¹Ì¿¬, ¼Ûº´Ã¶, ±è¼±È£, ±èÁ¤Èñ,
¼Ò¼Ó »ó¼¼Á¤º¸
±èÇýÁø ( Kim Hye-Jin ) - Veterans Health Service Medical Center Department of Conservative Dentistry
±è¹Ì¿¬ ( Kim Mi-Yeon ) - Veterans Health Service Medical Center Department of Conservative Dentistry
¼Ûº´Ã¶ ( Song Byung-Chul ) - Veterans Health Service Medical Center Department of Conservative Dentistry
±è¼±È£ ( Kim Sun-Ho ) - Veterans Health Service Medical Center Department of Conservative Dentistry
±èÁ¤Èñ ( Kim Jeong-Hee ) - Veterans Health Service Medical Center Department of Conservative Dentistry

Abstract


Purpose: The aim of this study was to evaluate the influence of polishing methods on the color stability of composite resins.

Materials and Methods: Two bulk-fill and four conventional resin composites were filled in cylindrical molds (6 mm diameter, 4 mm height) and light-cured. The specimens were stored in 34¡ÆC distilled water for 24 h. Spectrophotometer was used to determine the color value according to the CIE L*a*b* color space. Each group was divided into three groups according to polishing methods (n = 5). Group 1 was control group (Mylar strip group), group 2 was polished with PoGo, and group 3 was polished with Sof-Lex Spiral wheels. Color evaluation was performed weekly for 4 weeks after immersion in 34¡ÆC distilled water. The results were analyzed by generalized least squares method (P < 0.05).

Results: Generalized least squares analysis revealed that Sof-Lex Spiral wheels group showed the significantly lower ¥ÄE values compared to PoGo and control group (P < 0.05). The ¥ÄE values of polished group showed the significantly lower than the ¥ÄE values of unpolished group (P < 0.05). Regarding color changes of composite resins, there was no significant difference between the ¥ÄE values of Filtek Z250 and Filtek Z350 XT Universal restorative in all time intervals (P < 0.05). Tetric N-Ceram Bulk Fill showed the significantly lower ¥ÄE values compared to other composite resins in 1, 2, 3 weeks (P < 0.05).

Conclusion: Within the limitations of this study, polishing methods influence the color stabilities of composite resins. The group polished with Sof-Lex Spiral Wheels showed more resistance to discoloration than group polished with PoGo.

Å°¿öµå

¹úÅ©ÇÊ·¹Áø; »öÁ¶ ¾ÈÁ¤¼º; º¹ÇÕ·¹Áø; ¿¬¸¶ ¹æ¹ý
bulk-fill resin; color stability; composite resins; polishing methods; Sof-Lex Spiral wheels

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI