Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

CBCT ±â¹Ý µðÁöÅÐ ¾È±ÃÀÌÀü°ú ¾Æ³¯·Î±× ¾È±ÃÀÌÀüÀÇ À§Ä¡ ÆíÂ÷: Áõ·Êº¸°í

Positional deviation between CBCT-based digital facebow transfer and analog facebow transfer: case series

±¸°­È¸º¹ÀÀ¿ë°úÇÐÁö 2023³â 39±Ç 3È£ p.176 ~ 185
¹Ú¸íÇö, ¼ÕÅ«¹Ù´Ù, ¾ÈÈÖ±Õ, À̵ÎÇü, ±è¼Ò¿¬, À̺¹±Ô,
¼Ò¼Ó »ó¼¼Á¤º¸
¹Ú¸íÇö ( Park Myung-Hyun  ) - 
¼ÕÅ«¹Ù´Ù ( Son Keunbada ) - 
¾ÈÈÖ±Õ ( Ahn Hwi-Gyun ) - 
À̵ÎÇü ( Lee Du-Hyeong ) - 
±è¼Ò¿¬ ( Kim So-Yeun ) - 
À̺¹±Ô ( Lee Kyu-Bok ) - 

Abstract

Á¶Àý¼º ±³Çձ⿡ ¸ðÇüÀ» ºÎÂøÇϱâ À§ÇÏ¿© ¾È±ÃÀÌÀüÀÌ ÇÊ¿äÇÏ´Ù. ¾Æ³¯·Î±× ¾È±ÃÀÌÀü¿¡¼­´Â ÀåºñÀÇ Á¤È®µµ¿Í ÀÛ¾÷ÀÚÀÇ ¼÷·Ãµµ°¡ ¸ðÇü ºÎÂø °á°ú¿¡ ¿µÇâÀ» ¹ÌÄ¥ °¡´É¼ºÀÌ ÀÖ´Ù. ´õºÒ¾î ÆíÂ÷°¡ Å« ¹æ¹ýÀ¸·Î ºÎÂøµÈ ÀÛ¾÷ ¸ðÇü¿¡¼­´Â Á¤È®ÇÑ Ä¡°ú º¸Ã¶¹°ÀÇ Á¦ÀÛÀÌ ¾î·Á¿ì¹Ç·Î, ¾Æ³¯·Î±× ¾È±ÃÀÌÀüÀ¸·Î ºÎÂøµÈ ÀÛ¾÷ ¸ðÇüÀÇ À§Ä¡ ÆíÂ÷¸¦ ÆľÇÇÏ´Â °ÍÀÌ Áß¿äÇÏ´Ù. º» Áõ·Ê¿¡¼­´Â ¾Æ³¯·Î±× ¾È±ÃÀÌÀüÀ¸·Î ºÎÂøµÈ »ó¾Ç ¸ðÇüÀÇ À§Ä¡¿Í cone beam computed tomography µ¥ÀÌÅ͸¦ ±â¹ÝÀ¸·Î À§Ä¡µÈ »ó¾Ç ¸ðÇüÀÇ À§Ä¡¸¦ °Å¸® ÆíÂ÷¿Í ±³ÇÕ Æò¸éÀÇ °¢µµ ÆíÂ÷¸¦ Æò°¡ÇÏ¿´´Ù. À̸¦ Åä´ë·Î ¾Æ³¯·Î±× ¾È±ÃÀÌÀüÀ¸·Î ºÎÂøµÈ »ó¾Ç ¸ðÇüÀÇ ÆíÂ÷¸¦ º¸°íÇÏ¿´´Ù. ¾Æ³¯·Î±× ¾È±ÃÀÌÀü ¹æ¹ýÀº 3 - 16 mmÀÇ ¼±Çü ÆíÂ÷¿Í 5 - 7µµÀÇ ±³ÇÕÆò¸é °¢µµ ÆíÂ÷¸¦ °¡Áö´Â »ó¾Ç ¸ðÇüÀÇ ºÎÂø °á°ú¸¦ ³ªÅ¸³»¾ú´Ù. ¾Æ³¯·Î±× ¾È±ÃÀÌÀüÀº ȯÀÚº°·Î À§Ä¡ ÆíÂ÷°¡ ´Ù¸¦ ¼ö ÀÖÀ½À» È®ÀÎÇßÀ¸¸ç, Ä¡°ú º¸Ã¶¹° Á¦ÀÛ¿¡¼­ÀÇ ºÎÁ¤È®¼ºÀ» ÃÊ·¡ÇÒ °¡´É¼ºÀÌ ÀÖ´Ù. ÀÌ·¯ÇÑ °á°ú´Â ÀÓ»ó¿¡¼­ ¾Æ³¯·Î±× ¾È±ÃÀÌÀü ¹æ¹ýÀÌ »ó¾Ç ¸ðÇüÀ» ºÎÂøÇÏ´Â °úÁ¤¿¡¼­ Å« ÆíÂ÷°¡ ÀÖÀ» ¼ö ÀÖÀ½À» ³ªÅ¸³»¾ú±â¿¡ À̸¦ º¸°íÇÏ´Â ¹ÙÀÌ´Ù.

Facebow transfer is essential for accurately mounting a dental cast onto a semi-adjustable articulator. The precision of traditional analog facebow transfer is influenced by both the accuracy of the equipment used and the skill level of the operator. Considering that substantial positional deviations can adversely affect the quality of a fabricated dental prosthesis; it is critical to assess the positional accuracy of casts mounted using analog facebow transfer. This case report evaluates the linear and angular deviations of the occlusal plane for maxillary casts mounted through both analog facebow transfer and cone-beam computed tomography-based methods. The findings indicate that analog facebow transfer produced a linear deviation ranging from 3 to 16 mm and an angular deviation of the occlusal plane between 5 to 7 degrees. This case report confirms that, across two patients, analog facebow transfer can result in varying degrees of positional deviation, thereby potentially leading to inaccuracies in the fabrication of dental prostheses. These results suggest that, in clinical practice, the use of analog facebow transfer may yield significant deviations during the process of mounting maxillary casts.

Å°¿öµå

¾È±ÃÀÌÀü; CBCT; ¸ðÇü ºÎÂø; À§Ä¡ ÆíÂ÷; ±³ÇÕ Æò¸é; ¹ÝÁ¶Àý¼º ±³ÇÕ±â
facebow transfer; CBCT; mounting; positional deviation; occlusal plane; articulator

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

µîÀçÀú³Î Á¤º¸