The effect of thickness and translucency of polymer-infiltrated ceramic-network material on degree of conversion of resin cements

Journal of Advanced Prosthodontics 2020³â 12±Ç 2È£ p.61 ~ 66
Barutcigil Kubilay, Buyukkaplan Ulviye Sebnem,
¼Ò¼Ó »ó¼¼Á¤º¸
 ( Barutcigil Kubilay ) - Akdeniz University Faculty of Dentistry Department of Prosthodontics
 ( Buyukkaplan Ulviye Sebnem ) - Akdeniz University Faculty of Dentistry Department of Prosthodontics

Abstract


PURPOSE: The aim of the present study was to determine the degree of conversion of light- and dual-cured resin cements used in the cementation of all-ceramic restorations under different thicknesses of translucent (T) and high-translucent (HT) polymer-infiltrated ceramic-network (PICN) material.

MATERIALS AND METHODS: T and HT PICN blocks were prepared at 0.5, 1.0, 1.5, and 2.0 mm thicknesses (n=80). Resin cement samples were prepared with a diameter of 6 mm and a thickness of 100 ¥ìm. Light-cured resin cement was polymerized for 30 seconds, and dual-cure resin cement was polymerized for 20 seconds (n=180). Fourier transform infrared spectroscopy (FTIR) was used for degree of conversion measurements. The obtained data were analyzed with ANOVA and Tukey HSD, and independent t-test.

RESULTS: As a result of FTIR analysis, the degree of conversion of the light-cured resin cement prepared under 1.5- and 2.0-mm-thick T and HT ceramics was found to be lower than that of the control group. Regarding the degree of conversion of the dual-cured resin cement group, there was no significant difference from the control group.

CONCLUSION: Within the limitation of present study, it can be concluded that using of dual cure resin cement can be suggested for cementation of PICN material, especially for thicknesses of 1.5 mm and above.

Å°¿öµå

Hybrid ceramic; Resin cement; Degree of Conversion; Fourier transform infrared spectroscopy (FTIR)