Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Comparison of fracture strength after thermo-mechanical aging between provisional crowns made with CAD/CAM and conventional method

Journal of Advanced Prosthodontics 2020³â 12±Ç 4È£ p.218 ~ 224
Reeponmaha Tanapon, Angwaravong Onauma, Angwarawong Thidarat,
¼Ò¼Ó »ó¼¼Á¤º¸
 ( Reeponmaha Tanapon ) - Khon Kaen University Faculty of Dentistry Department of Prosthodontics
 ( Angwaravong Onauma ) - Khon Kaen University Faculty of Dentistry Department of Preventive Dentistry
 ( Angwarawong Thidarat ) - Khon Kaen University Faculty of Dentistry Department of Prosthodontics

Abstract


PURPOSE: The objectives of this study were to evaluate the fracture strength and fracture patterns of provisional crowns fabricated from different materials and techniques after receiving stress from a simulated oral condition.

MATERIALS AND METHODS: A monomethacrylate-based resin (Unifast Trad) and a bis-acryl-based (Protemp 4) resin were used to fabricate provisional crowns using conventional direct technique. A milled monomethacrylate resin (Brylic Solid) and a 3D-printed bis-acrylate resin (Freeprint Temp) were chosen to fabricate provisional crowns using the CAD/CAM process. All cemented provisional crowns (n=10/group) were subjected to thermal cycling (5,000 cycles at 5¡Æ?55¡É) and cyclic occlusal load (100 N at 4 Hz for 100,000 cycles). Maximum force at fracture was tested using a universal testing machine.

RESULTS: Maximum force at fracture (mean ¡¾ SD, N) of each group was 657.87 ¡¾ 82.84 for Unifast Trad, 1125.94 ¡¾ 168.07 for Protemp4, 953.60 ¡¾ 58.88 for Brylic Solid, and 1004.19 ¡¾ 122.18 for Freeprint Temp. One-way ANOVA with Tamhane post hoc test showed that the fracture strength of Unifast Trad was statistically significantly lower than others (P<.01). No statistically significant difference was noted among other groups. For failure pattern analysis, Unifast Trad and Brylic Solid showed less damage than Protemp 4 and Freeprint Temp groups.

CONCLUSION: Provisional crowns fabricated using the CAD/CAM process and the conventionally fabricated bis-acryl resins exhibited significant higher fracture strength compared to conventionally fabricated monomethacrylate resins after the aging regimen. Therefore, CAD/CAM milling and 3D printing of provisional restorations may be good alternatives for long term provisionalization.

Å°¿öµå

Computer-aided design/computer-aided manufacturing (CAD/CAM); 3D printing; Fracture strength; Provisional restorations

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

SCI(E)
KCI
KoreaMed