Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies

Restorative Dentistry & Endodontics 2015³â 40±Ç 1È£ p.23 ~ 29
Bastos Laura Alves, Sousa Ana Beatriz Silva, Drubi-Filho Brahim, Pires-de-Souza Fernanda de Carvalho Panzeri, Garcia Lucas da Fonseca Roberti,
¼Ò¼Ó »ó¼¼Á¤º¸
 ( Bastos Laura Alves ) - University of Sao Paulo Ribeirao Preto Medical School Department of Dental Materials and Prosthodontics
 ( Sousa Ana Beatriz Silva ) - University of Sao Paulo Ribeirao Preto Medical School Department of Dental Materials and Prosthodontics
 ( Drubi-Filho Brahim ) - University of Sao Paulo Ribeirao Preto Medical School Department of Dental Materials and Prosthodontics
 ( Pires-de-Souza Fernanda de Carvalho Panzeri ) - University of Sao Paulo Ribeirao Preto Medical School Department of Dental Materials and Prosthodontics
 ( Garcia Lucas da Fonseca Roberti ) - University of Sao Paulo Ribeirao Preto Medical School Department of Dental Materials and Prosthodontics

Abstract


Objectives: The aim of this study was to evaluate the effect of pre-etching on the bond strength of silorane-based composite specific adhesive system to dentin.

Materials and Methods: Thirty human molars were randomly divided into 5 groups according to the different bonding strategies. For teeth restored with silorane-based composite (Filtek Silorane, 3M ESPE), the specific self-etching adhesive system (Adhesive System P90, 3M ESPE) was used with and without pre-etching (Pre-etching/Silorane and Silorane groups). Teeth restored with methacrylate based-composite (Filtek Z250, 3M ESPE) were hybridized with the two-step self-etching system (Clearfil SE Bond, Kuraray), with and without pre-etching (Pre-etching/Methacrylate and Methacrylate groups), or three-step adhesive system (Adper Scotchbond Multi-Purpose, 3M ESPE) (Three-step/Methacrylate group) (n = 6). The restored teeth were sectioned into stick-shaped test specimens (1.0 ¡¿ 1.0 mm), and coupled to a universal test machine (0.5 mm/min) to perform microtensile testing.

Results: Pre-etching/Methacrylate group presented the highest bond strength values, with significant difference from Silorane and Three-step/Methacrylate groups (p < 0.05). However, it was not significantly different from Preetching/Silorane and Methacrylate groups.

Conclusions: Pre-etching increased bond strength of silorane-based composite specific adhesive system to dentin.

Å°¿öµå

Adhesive system; Bond strength; Low-shrinkage; Silorane based-composite

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

  

µîÀçÀú³Î Á¤º¸

KCI
KoreaMed