In vitro evaluation of a newly produced resin-based endodontic sealer

Restorative Dentistry & Endodontics 2016³â 41±Ç 3È£ p.189 ~ 195
Song Yoo-Seok, ÃÖÀ¯¸®³ª, ÀÓ¸íÁø, À¯¹Ì°æ, È«ÂùÀÇ, À̱¤¿ø, ¹Î°æ»ê,
¼Ò¼Ó »ó¼¼Á¤º¸
 ( Song Yoo-Seok ) - Chonbuk National University School of Dentistry Department of Conservative Dentistry
ÃÖÀ¯¸®³ª ( Choi Yoorina ) - Wonkwang University Dental Hospital Department of Conservative Dentistry
ÀÓ¸íÁø ( Lim Myung-Jin ) - Chonbuk National University School of Dentistry Department of Conservative Dentistry
À¯¹Ì°æ ( Yu Mi-Kyung ) - Chonbuk National University School of Dentistry Department of Conservative Dentistry
È«ÂùÀÇ ( Hong Chan-Ui ) - Dankook University School of Dentistry Department of Conservative Dentistry
À̱¤¿ø ( Lee Kwang-Won ) - Chonbuk National University School of Dentistry Department of Conservative Dentistry
¹Î°æ»ê ( Min Kyung-San ) - Chonbuk National University School of Dentistry Department of Conservative Dentistry

Abstract


Objectives: A variety of root canal sealers were recently launched to the market. This study evaluated physicochemical properties, biocompatibility, and sealing ability of a newly launched resin-based sealer (Dia-Proseal, Diadent) compared to the existing root canal sealers (AHplus, Dentsply DeTrey and ADseal, Metabiomed).

Materials and Methods: The physicochemical properties of the tested sealers including pH, solubility, dimensional change, and radiopacity were evaluated. Biocompatibility was measured using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay. For microleakage test, single-rooted teeth were instrumented, and obturated with gutta-percha and one of the sealers (n = 10). After immersion in 1% methylene blue solution for 2 weeks, the specimens were split longitudinally. Then, the maximum length of staining was measured. Statistical analysis was performed by one-way analysis of variance followed by Tukey test (p = 0.05).

Results: Dia-Proseal showed the highest pH value among the tested sealers (p < 0.05). ADseal showed higher dimensional change compared to AHplus and Dia-Proseal (p < 0.05). The solubility values of AHplus and Dia-Proseal were similar, whereas ADseal had the lowest solubility value (p < 0.05). The flow values of sealer in increasing order were AHplus, DiaProseal, and ADseal (p < 0.05). The radiopacity of AHplus was higher than those of ADseal and Dia-Proseal (p < 0.05). The cell viability of the tested materials was statistically similar throughout the experimental period. There were no significant differences in microleakage values among the tested samples.

Conclusions: The present study indicates that Dia-Proseal has acceptable physicochemical properties, biocompatibility, and sealing ability.

Å°¿öµå

Biocompatibility; Microleakage; Physicochemical; Sealer