Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Shade reproduction and the ability of lithium disilicate ceramics to mask dark substrates

Restorative Dentistry & Endodontics 2020³â 45±Ç 3È£ p.41 ~ 41
Iravani Maryam, Shamszadeh Sayna, Panahandeh Narges, Sheikh-Al-Eslamian Seyedeh Mahsa, Torabzadeh Hassan,
¼Ò¼Ó »ó¼¼Á¤º¸
 ( Iravani Maryam ) - Shahid Beheshti University of Medical Sciences Faculty of Dentistry Department of Restorative
 ( Shamszadeh Sayna ) - Shahid Beheshti University of Medical Sciences Research Institute of Dental Sciences Dental Research Center
 ( Panahandeh Narges ) - Shahid Beheshti University of Medical Sciences Research Institute of Dental Sciences Dental Research Center
 ( Sheikh-Al-Eslamian Seyedeh Mahsa ) - Shahid Beheshti University of Medical Sciences Research Institute of Dental Sciences Dental Research Center
 ( Torabzadeh Hassan ) - Shahid Beheshti University of Medical Sciences Research Institute of Dental Sciences Dental Research Center

Abstract


Objectives: This study aimed to evaluate the ability of lithium disilicate ceramics to reproduce the A2 shade and to mask A4 substrates.

Materials and Methods: Twenty-four discs (8 mm in diameter, shade A2) of high translucency (groups 1?3) and low translucency (groups 4?6) of IPS e.max ceramic with different thicknesses (0.5, 0.75, and 1 mm) were fabricated as monolithic structures. In addition, discs of medium opacity (group 7?8) with different core/veneer combinations (0.3 mm/0.7 mm and 0.5 mm/0.5 mm) were fabricated as bilayer structures. Specimens were superimposed on an A4 substrate (complex). The color changes of the complex were measured using a spectrophotometer on a black background, and the ¥ÄE values of the complex were compared with either the A4 substrate or the A2 shade tab. One-way analysis of variance, the Tukey honest significant difference test, and the Fisher test were used to analyze the data (p < 0.05).

Results: Significant between-group differences were found for comparisons to both the A4 substrate and the A2 shade (p < 0.05). When compared with the A4 substrate, the ¥ÄE values in all groups were in the non-acceptable range. When compared with the A2 shade, the ¥ÄE values in all groups, except groups 2 and 3, were in the clinically acceptable range.

Conclusions: All translucencies and thicknesses masked the underlying dark substrate. However, the low-translucency IPS e.max Press better reproduced the A2 shade.