Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Effectiveness of endodontic retreatment using WaveOne Primary files in reciprocating and rotary motions

Restorative Dentistry & Endodontics 2023³â 48±Ç 2È£ p.15 ~ 15
Patricia Marton Costa, Renata Maira de Souza Leal, Guilherme Hiroshi Yamanari, Bruno Cavalini Cavenago, Marco Antonio Hungaro Duarte,
¼Ò¼Ó »ó¼¼Á¤º¸
 ( Patricia Marton Costa ) - 
 ( Renata Maira de Souza Leal ) - 
 ( Guilherme Hiroshi Yamanari ) - 
 ( Bruno Cavalini Cavenago ) - 
 ( Marco Antonio Hungaro Duarte ) - 

Abstract


Objectives: This study evaluated the efficiency of WaveOne Primary files (Dentsply Sirona) for removing root canal fillings with 2 types of movement: reciprocating (RCP) and continuous counterclockwise rotation (CCR).

Materials and Methods: Twenty mandibular incisors were prepared with a RCP instrument (25.08) and filled using the Tagger hybrid obturation technique. The teeth were retreated with a WaveOne Primary file and randomly allocated to 2 experimental retreatment groups (n = 10) according to movement type: RCP and CCR. The root canals were emptied of filling material in the first 3 steps of insertion, until reaching the working length. The timing of retreatment and procedure errors were recorded for all samples. The specimens were scanned before and after the retreatment procedure with micro-computed tomography to calculate the percentage and volume (mm3) of the residual filling material. The results were statistically evaluated using paired and independent t-tests, with a significance level set at 5%.

Results: No significant difference was found in the timing of filling removal between the groups, with a mean of 322 seconds (RCP) and 327 seconds (CCR) (p < 0.05). There were 6 instrument fractures: 1 in a RCP motion file and 5 in continuous rotation files. The volumes of residual filling material were similar (9.94% for RCP and 15.94% for CCR; p > 0.05).

Conclusions: The WaveOne Primary files used in retreatment performed similarly in both RCP and CCR movements. Neither movement type completely removed the obturation material, but the RCP movement provided greater safety.

Å°¿öµå

Endodontics; Micro-computed tomography, X-ray; Retreatment