Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

ºûÀÇ ÆÄÀåÀÌ º¹ÇÕ·¹ÁøÀÇ °æµµ¿Í ÁßÇÕ¼öÃà¿¡ ¹ÌÄ¡´Â ¿µÇâ

Effects of light wavelength on the microhardenss and polymerization shrinkage of composite resins

´ëÇÑÄ¡°úÀç·áÇÐȸÁö 2017³â 44±Ç 4È£ p.367 ~ 376
±è½Â¼­, ¼³È¿Á¤, ±Ç¿ëÈÆ,
¼Ò¼Ó »ó¼¼Á¤º¸
±è½Â¼­ ( Kim Seung-Seo ) - ºÎ»ê´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úÀç·áÇб³½Ç
¼³È¿Á¤ ( Seol Hyo-Joung ) - ºÎ»ê´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úÀç·áÇб³½Ç
±Ç¿ëÈÆ ( Kwon Yong-Hoon ) - ºÎ»ê´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úÀç·áÇб³½Ç

Abstract

±¤ °³½Ã¸¦ À§ÇÏ¿© ±¤¿ø(ÆÄÀå)ÀÇ ¼±ÅÃÀº ÁßÇÕÀÇ °á°ú¿¡ ¿µÇâÀ» ¹ÌÄ£´Ù. º» ¿¬±¸´Â ±¤¿øÀÇ ÆÄÀåÀÌ º¹ÇÕ·¹ÁøÀÇ ÁßÇÕ¿¡ ¹ÌÄ¡´Â ¿µÇâÀ» Æò°¡ÇÑ °ÍÀÌ´Ù. À̸¦ À§ÇÏ¿© 4°¡ÁöÀÇ ±¤Á¶»ç À¯´Ö°ú 3Á¾ÀÇ º¹ÇÕ·¹ÁøÀ» »ç¿ëÇÏ¿´°í ±¤ Á¶»çµÈ ½Ã·á´Â ¹Ì¼¼°æµµ¿Í ÁßÇÕ¼öÃàÀ» Æò°¡ÇÏ¿´´Ù. ±× °á°ú ±¤ °³½ÃÁ¦·Î camphorquinone°ú coinitiator¸¦ ÇÔÀ¯ÇÑ ·¹ÁøÀº 473 nmÀÇ ÆÄÀåÀ» °¡Áö´Â ·¹ÀÌÀú¿¡ ÀÇÇØ ½Ã·á Ç¥¸éÀÇ ¹Ì¼Ò°æµµ°¡ 405À̳ª 457 nm ÆÄÀåÀÇ ·¹ÀÌÀú ¶§º¸´Ù ´Ù¼Ò ³·¾Ò´Ù. 405 nm ·¹ÀÌÀúÀÇ °æ¿ì´Â camphorquinone¸¸ ÇÔÀ¯ÇÑ ·¹Áø¿¡¼­ °¡Àå ³·Àº ¹Ì¼Ò°æµµ¸¦ º¸¿´´Ù. ½Ã·áÀÇ ¹Ù´Ú¸é¿¡¼­´Â ±¤¿øÀÇ ÆÄÀåÀÌ 405¿¡¼­ 473 nm·Î Áõ°¡ÇÒ¼ö·Ï ¹Ì¼Ò°æµµµµ Áõ°¡ÇÏ¿´´Ù. ÁßÇÕ¼öÃàÀÇ °æ¿ì LED¸¦ ±¤¿øÀ¸·Î ÇÑ °æ¿ì°¡ °¡Àå Å« ¼öÃà°ªÀ» º¸¿´´Ù. À̸¦ ÅëÇغ» ¿¬±¸´Â ÆĶõ»öÀÇ ·¹ÀÌÀú°¡ LED ±¤¿øó·³ ´Ù¾çÇÑ º¹ÇÕ·¹ÁøÀ» ÁßÇÕÇÒ ¼ö ÀÖ´Â °¡´É¼ºÀ» Á¦½ÃÇÏ¿´´Ù.

As an activator of photoinitiator, the selection of a light source (wavelength) can affect the result of polymerization. This study examined how the wavelength of a light source affects the curing of composite resins. Four light-curing units (LCUs) (405, 457, and 473 nm lasers with 530 mW/cm2 and one light-emitting diode (LED) with 900 mW/cm2) and three composite resins (one only camphorquinone-containing and two camphorquinone+coinitiator-containing as an initiator) were used. To determine the degree of polymerization, the microhardness and polymerization shrinkage were assessed. On the top surface, two camphorquinone+coinitiator-containing specimens cured using the 473 nm laser showed slightly lower microhardness than those cured using the 405 and 457 nm lasers. However, specimen that contains only camphorquinone showed the lowest microhardness when cured using the 405 nm laser. On the bottom surface, the microhardness increased gradually as laser wavelength changed from 405 to 473 nm. The specimens cured using the LED LCU showed the highest polymerization shrinkage compared to that by the lasers. This study highlights the potential of blue lasers on the curing of various composite resins to the level that the LED LCU can achieve.

Å°¿öµå

º¹ÇÕ·¹Áø; ºûÀÇ ÆÄÀå; ¹Ì¼¼°æµµ; ÁßÇÕ¼öÃà
Composite resin; Light wavelength; Microhardness; Polymerization shrinkage

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI