Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Effects of an electric toothbrush combined with 3-color light-emitting diodes on antiplaque and bleeding control: a randomized controlled study

Journal of Periodontal & Implant Science 2020³â 50±Ç 4È£ p.251 ~ 259
±ÇÂ÷°æ, ÀÌÀç¸ñ, ¼­Á¶¿µ, Seo Seung-Jun, ÀÌ¿µ±Õ, ±è¿ë°Ç,
¼Ò¼Ó »ó¼¼Á¤º¸
±ÇÂ÷°æ ( Kwon Cha-Kyoung ) - Kyungpook National University School of Dentistry Department of Periodontology
ÀÌÀç¸ñ ( Lee Jae-Mok ) - Kyungpook National University School of Dentistry Department of Periodontology
¼­Á¶¿µ ( Suh Jo-Young ) - Kyungpook National University School of Dentistry Department of Periodontology
 ( Seo Seung-Jun ) - Kyungpook National University School of Dentistry Department of Periodontology
ÀÌ¿µ±Õ ( Lee Young-Kyun ) - Kyungpook National University School of Dentistry Department of Biochemistry
±è¿ë°Ç ( Kim Yong-Gun ) - Kyungpook National University School of Dentistry Department of Periodontology

Abstract


Purpose: This randomized controlled study aimed to evaluate the effects of an electric toothbrush with 3 colors of light-emitting diodes (LEDs) on antiplaque and bleeding control.

Methods: This randomized, placebo-controlled, double-blinded, parallel-group clinical trial included 50 healthy adults with gingivitis, who were randomly assigned to 2 groups. The experimental group used electric toothbrushes with 3 colors of LEDs and the control group used the same electric toothbrush as the experimental group, but with LED sources with one-hundredth of the strength. The subjects used the electric toothbrush 3 times a day for 4 minutes each time. As clinical indices, bleeding on marginal probing (BOMP), the Loe-Silness gingival index (GI), and the Turesky-Quigley-Hein plaque index (QHI) were assessed at baseline, at 3 weeks, and at 6 weeks.

Results: There were significant decreases in all clinical indices (BOMP, GI, QHI) in both the experimental and control groups compared to baseline at 3 weeks and at 6 weeks. In a comparison between the experimental and control groups, no statistically significant differences were observed for any clinical indices at 3 weeks (P>0.05). However, at 6 weeks, statistically significant differences were observed between the experimental and control groups in BOMP and GI, which are indicators of gingival inflammation (P<0.05).

Conclusions: This study demonstrated that an electric toothbrush combined with 3-color LEDs reduced gingival bleeding and inflammation after 6 weeks.

Å°¿öµå

Biofilm; Dental plaque; Gingivitis; Toothbrushing

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

SCI(E)
KCI
KoreaMed